This document is sold as an engineer-certified report for permitting ICP: Split Units meeting model numbers listed below. The document meets the requirements of the structural wind integrity per the selected building code above using ASCE 7 for the structural approval of unit housing and tie-down clip capacities. This report will be signed and sealed by a Professional Engineer of the firm when purchased and delivered to you via email (using the digital seal method, within 24 hours) or mail (UPS Ground for printed and signed hardcopies, next day in South Florida). Use it with your site-specific documents to obtain a building permit. (Former TER #20-33368)

Digitally certified documents are licensed to the provided contractor and zip code up to the time frame listed. For extensions beyond that date, use the Online Chat to request an extension.

This report applies to the following model numbers:

Unit Model Unit Dimensions (in) Unit Model Unit Dimensions (in)
Width Depth Height Width Depth Height
*CA724 31.19 31.19 36.38 C4H5S18*K*AA 31 3/16 31 3/16 28.6875
*CA736 31.19 31.19 36.38 C4H5S24*K*AA 31 3/16 31 3/16 32.125
*CA748 35 35 40.63 C4H5S30*K*AA 31 3/16 31 3/16 28.6875
*CA760 35 35 40.63 C4H5S36*K*AA 31 3/16 31 3/16 28.6875
*CA924 35 35 40.63 C4H5S42*K*AA 31 3/16 31 3/16 32.125
*CA936 35 35 47.44 C4H5S48*K*AA 31 3/16 31 3/16 35.5
*CA948 35 35 47.44 C4H5S60*K*AA 35 35 40.375
*CA960 35 35 47.44 C4H7T24*K*AA 35 35 37
*CH624 35 35 40.63 C4H7T36*K*AA 35 35 40 3/8
*CH636 35 35 40.63 C4H7T48*K*AA 35 35 47  3/16
*CH648 35 35 40.63 C4H7T60*K*AA 35 35 47  3/16
*CH660 35 35 47.44 H4A6S18*K*WA 31 3/16 31 3/16 32 1/8
*CH924 35 35 40.63 H4A6S24*K*WA 31 3/16 31 3/16 32 1/8
*CH936 35 35 44.06 H4A6S30*K*WA 31 3/16 31 3/16 35 1/2
*CH948 35 35 47.44 H4A6S36*K*WA 31 3/16 31 3/16  38 15/16
*CH960 35 35 47.44 H4A6S42*K*WA 31 3/16 31 3/16 32 1/8
*SA618 31.19 31.19 29.56 H4A6S48*K*WA 31 3/16 31 3/16 32 1/8
*SA624 31.19 31.19 29.05 H4A6S49*K*WA 35 35 45 11/16
*SA630 31.19 31.19 32.94 H4A6S60*K*WA 31 3/16 31 3/16  38 15/16
*SA636 35 35 30.44 H4A6S61*K*WA 35 35 45 11/16
*SA642 35 35 40.63 H4H5S18*K*AA 31 3/16 31 3/16 28.6875
*SA648 35 35 40.63 H4H5S24*K*AA 31 3/16 31 3/16 32.125
*SA660 35 35 47.44 H4H5S30*K*AA 31 3/16 31 3/16 28.6875
*SH518 31.19 31.19 29.56 H4H5S36*K*AA 31 3/16 31 3/16 28.6875
*SH524 35 35 33.88 H4H5S42*K*AA 31 3/16 31 3/16 32.125
*SH530 35 35 37.25 H4H5S48*K*AA 31 3/16 31 3/16 35.5
*SH536 35 35 37.25 H4H5S60*K*AA 35 35 40.375
*SH542 35 35 30.44 H4H7T24*K*AA 35 35 37
*SH548 35 35 33.88 H4H7T36*K*AA 35 35 40.375
*SH560 35 35 40.63 H4H7T48*K*AA 35 35 47.1875
*VA924 23.13 23.13 31.63 H4H7T60*K*AA 35 35 47.1875
*VA925 23.13 23.13 38.44 T4A6S18*K*WA 31 3/16 31 3/16 32 1/8
*VA936 23.13 23.13 38.44 T4A6S24*K*WA 31 3/16 31 3/16 32 1/8
*VA937 31.19 31.19 39.75 T4A6S30*K*WA 31 3/16 31 3/16 35 1/2
*VA948 31.19 31.19 39.75 T4A6S36*K*WA 31 3/16 31 3/16  38 15/16
*VA949 35 35 44 T4A6S42*K*WA 31 3/16 31 3/16 32 1/8
*VA960 31.19 31.19 43.19 T4A6S48*K*WA 31 3/16 31 3/16 32 1/8
*VH824 23.13 23.13 31.63 T4A6S49*K*WA 35 35 45 11/16
*VH825 23.13 23.13 38.44 T4A6S60*K*WA 31 3/16 31 3/16  38 15/16
*VH836 23.13 23.13 31.63 T4A6S61*K*WA 35 35 45 11/16
*VH837 31.19 31.19 39.75 T4H5S18*K*AA 31 3/16 31 3/16 28.6875
*VH848 31.19 31.19 38.44 T4H5S24*K*AA 31 3/16 31 3/16 32.125
*VH860 31.19 31.19 43.19 T4H5S30*K*AA 31 3/16 31 3/16 28.6875
C4A6S18*K*WA 31 3/16 31 3/16 32 1/8 T4H5S36*K*AA 31 3/16 31 3/16 28.6875
C4A6S24*K*WA 31 3/16 31 3/16 32 1/8 T4H5S42*K*AA 31 3/16 31 3/16 32.125
C4A6S30*K*WA 31 3/16 31 3/16 35 1/2 T4H5S48*K*AA 31 3/16 31 3/16 35.5
C4A6S36*K*WA 31 3/16 31 3/16  38 15/16 T4H5S60*K*AA 35 35 40.375
C4A6S42*K*WA 31 3/16 31 3/16 32 1/8 T4H7T24*K*AA 35 35 37
C4A6S48*K*WA 31 3/16 31 3/16 32 1/8 T4H7T36*K*AA 35 35 40.375
C4A6S49*K*WA 35 35 45 11/16 T4H7T48*K*AA 35 35 47.1875
C4A6S60*K*WA 31 3/16 31 3/16  38 15/16 T4H7T60*K*AA 35 35 47.1875
C4A6S61*K*WA 35 35 45 11/16

What is a TER and how is it used for permitting?

What’s the difference between a TER and a Miami Dade NOA or FL Product Approval?

What do I do if a TER isn’t enough for a permit?

What Doesn’t a TER Do?

Read More
Please select the state you would like the document certified in
This field can't be Empty
This field can't be Empty
This field can't be Empty
Save up to an additional 33% by using tokens Learn more

Read Disclaimer & Important Information for Use
Weight 0.05 lbs
Dimensions 0.0100 × 8.5000 × 11.0000 in
Plan Format

Digitally Sealed E-Permit File, Raised Sealed Hardcopy

Brand

Carrier, ICP

Plan Designer

Engineering Express

Plan Type

Technical Evaluation Report-TER, Manufacturer Plans

Storefront

Carrier, Engineering Express

Please sign in or create a free account
to use Favorites
Scroll to Top