Description

This certification is applicable to Structall’s Wall Panel System – Steel Skin. It contains numerous dimension, wind speed/pressure, and component options for many common Structall applications. It is sold as an engineered sealed document and meets the requirements of the applicable building code for the approval of structural adequacy only. Use it in conjunction with your other approved documents to obtain a building permit.

This certification is generic and installations beyond this scope or site specific applications shall require custom engineering that can be performed by Engineering Express. Click here to request a quote.

For states not listed here, please contact us.

 

PANEL PROPERTIES:

  1. PANEL STRUCTURAL PROPERTIES DERIVED FROM CERTIFIED TEST REPORTS TT509014A, TT509014B & TT506010 BY TERRAPIN TESTING; TEST REPORT #STRL-001-02-02 BY PRI CONSTRUCTION MATERIALS TECHNOLOGIES; TEST REPORTS TT-506027B, 506027C, 506027D, 509014A, 509014B  BY TERRAPIN TESTING, ESP012351P-1, ESP012351P-2, ESP012351P-3, ESP012351P-3A, ESP012351P-4, ESP012351P-5, ESP012351P-6, EXP012351P-6A, ESP012351P-7, ESP012351P-8, ESP012351P-9, ESP012351P-9A BY ELEMENT MATERIALS TECHNOLOGY.
  2. ALLOWABLE LOAD VALUES ARE DERIVED FROM THE TEST REPORTS OUTLINED HEREIN AS WELL AS ICC REPORT #ESR-3152
  3. PANEL DEAD LOADS HAVE NOT BEEN FACTORED INTO CALCULATIONS FOR WALL PANEL PROPERTIES.
  4. PANEL DEAD LOADS HAVE BEEN FACTORED INTO CALCULATIONS FOR ROOF PANEL PROPERTIES.

RECOMMENDED DEFLECTION NOTES:

  1. USE L/80 FOR ALL EXTERIOR WALLS AND INTERIOR PARTITIONS SUPPORTING SCREEN-WALLED ROOMS.
  2. USE L/80 FOR ALL MEMBERS SUPPORTING WALLS IN THE HVHZ WITH A SPAN LESS THAN OR EQUAL TO 12′-0″.
  3. USE L/80 FOR GROUP R-3 OCCUPANCIES ONLY, WITH WALL PANELS OF CARPORTS, CANOPIES, PATIO COVERS, UTILITY SHEDS AND SIMILAR MINOR STRUCTURES THAT ARE NOT CONSIDERED LIVING AREAS, WHERE THE ROOF PROJECTION IS 12 FEET OR LESS IN THE DIRECTION OF THE SPAN AND FOR MEMBERS SUPPORTING SCREENS ONLY. (HVHZ ONLY).
  4. USE L/120 FOR ALL EXTERIOR WALLS AND INTERIOR PARTITIONS WITH FLEXIBLE FINISHES.
  5. USE L/180 FOR ALL MEMBERS SUPPORTING WALLS IN THE HVHZ WITH A SPAN GREATER THAN 12′-0″.
  6. USE L/180 FOR ALL VERTICAL MEMBERS NOT REQUIRED TO SUPPORT MATERIAL THAT HARDENS IN PLACE, IS BRITTLE OR LACKS RESISTANCE TO CRACKING CAUSED BY BENDING STRAINS. (HVHZ ONLY).
  7. USE L/240 FOR ALL EXTERIOR WALLS AND INTERIOR PARTITIONS WITH BRITTLE FINISHES.

For variations of this plan, click here - select 'Revision To One Of Our Projects' when asked, & reference the MPS SKU number listed herein.

Additional information

Weight 0.64 oz
Dimensions 0.08 × 17 × 11 in
Plan Type

Manufacturer-Based Plan, Master Plan Sheet – MPS

Plan Designer

Engineering Express

Brand

Structall Building Systems, Inc.

Material

Steel

Plan Format

Digitally Sealed File, Sealed Hardcopy

Reviews

There are no reviews yet.

Be the first to review “EPS Foam Core Wall Panels – Steel Skin (MPS 15-2937)”